CPACINC.COM

Computer and IT Solutions Professionals

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Process Calibrator

MODEL 123

  • 4-20mA, 0-20mA, 0-24mA with 1mA resolution
  • 0-100mV with 10mV resolution
  • 0-12V with 1mV resolution
  • Thermocouple K,J,E,T TYPE 1oC 1oF resolution
  • Frequency 2 - 50,000Hz

PROVA 123

PROVA 123 Specification

Electrical Specification: (23 +/- 5 oC for one year)
Range
Resolution
Accuracy
Max load
4-20 mA,0-20mA,0-24mA
1mA
0.025%+-3mA
24mA-1k ohm 24V
0-12.000V
1mV
0.05%+-3mV
1mA
0-1.0000V
100mV
0.05%+-.3mV
1mA
0-100.00mV
10mV
0.05%+-30mV
1mA
Frequency 2-50,000 Hz
0.005%+-2 dgts
1k ohm
-200oC -0oC K type
1oC 1oF
0.1%+-1.2oC
1k ohm
0-1370oC K type
1oC 1oF
0.05%+-0.8oC
1k ohm
-100oC - 0oC J type
1oC 1oF
0.1%+-1oC
1k ohm
0-760oC J type
1oC 1oF
0.05%+-0.7oC
1k ohm
-100oC -0oC E type
1oC 1oF
0.1%+-0.9oC
1k ohm
0-850oC E type
1oC 1oF
0.05%+-0.7oC
1k ohm
-200oC -0oC T type
1oC 1oF
0.1%+-1.2oC
1k ohm
0-400oC T type
1oC 1oF
0.05%+-0.8oC
1k ohm

General Specification:
Battery Type: 9V Rechargeable Battery
Display: 2 x 5 Digits Dual Display LCD
Operating Humidity: Less than 80% RH
Storage Temperature: -40oC~60oC (-40oF~140oF)
Dimension: Meter: 3.46" x 6.61" x 1.03"
88mm(L) x 168mm(W) x 26.2mm(H)
Weight: 350g/12.34 oz. (Battery included)
Accessories: Carrying case x 1
User manual x 1
9V Rechargeable Battery x 1