| Measurement Range |
Humidity 10%¡K 95%R.H.
Temperature -20oC..+ 60oC
4oF¡K+140oF
|
| Resolution |
0.1% R.H. 0.1oC,
0.1oF |
| Accuracy |
Humidity +/- 3%R.H. (at
25oC, 30¡K95%R.H.)
Temperature +/- 0.8oC, +/- 1.5oF |
| Sensor type |
Humidity----------precision
capacitance sensor
Temperature---semiconductor sensor |
| Response time |
Humidity 45%R.H.--- 95%R.H.
<= 3min
95%R.H.--- 45%R.H. <= 5min
Temperature 5 sec./10oC |
| Sampling rate |
1 time per second |
| Record (Data logging) |
7000 Point Data logger
(Dual Data) |
| Operating temperature
and humidity |
0oC to 40oC
, below 80% R.H. |
| Storage temperature
and humidity |
-10oC to 60oC
, below 70% R.H. |
| Power supply |
006P 9V or IEC6F22, NEDA
1604 battery |
| Battery life |
Approx. 50hours (Alkaline) |
| Dimensions |
270(L)¡Ñ68(W)¡Ñ25mm(H),
10.6"(L)¡Ñ2.7"(W)¡Ñ1"(H) |
| Weight |
Approx. 200g, (7.1oz) |
| Accessories |
Instruction manual, Battery,
Carry case, Software,
RS-232 cable, 9 Pin to 25 Pin gender changer. |